Search results for "Bioresorbable scaffold"
showing 10 items of 11 documents
TCT-408 Thirty-day Outcome Following Polymeric Bioresorbable Scaffold Implantation in 347 STEMI Patients Enrolled in the Multicenter “Registro Absorb…
2016
Cardiac Computed Tomography Angiography Follow-Up of Resorbable Magnesium Scaffolds.
2021
Abstract Introduction An ancillary advantage of bioresorbable scaffolds is the possibility of non-invasive imaging assessment of the treated coronary segment. Cardiac computed tomography angiography (CCTA) studies of resorbable magnesium scaffolds (RMS) are scarce. Methods In this collaborative, international study, nine patients who had an RMS implanted underwent CCTA as part of follow-up assessment. Core-lab blinded quantitative and qualitative assessment was performed by an independent CCTA investigator. Results Eight studies were amenable for quantitative analysis, and the blinded CT investigator successfully located and evaluated patency of RMS in all cases. The CCTA follow-up in-scaff…
Contemporary practice and technical aspects in coronary intervention with bioresorbable scaffolds : a European perspective
2015
Aims Next to patient characteristics, the lack of a standardised approach for bioresorbable vascular scaffold (BVS) implantation is perceived as a potential explanation for the heterogeneous results reported so far. To provide some guidance, we sought to find a consensus on the best practices for BVS implantation and management across a broad array of patient and lesion scenarios. Methods and results Fourteen European centres with a high volume of BVS procedures combined their efforts in an informal collaboration. To get the most objective snapshot of different practices among the participating centres, a survey with 45 multiple choice questions was prepared and conducted. The results of th…
Absorb Bioresorbable Scaffold Versus Xience Metallic Stent for Prevention of Restenosis Following Percutaneous Coronary Intervention in Patients at H…
2019
Abstract Background The advent of bioresorbable vascular scaffolds (BVS) was considered as a potential improvement in percutaneous coronary intervention (PCI) after the groundbreaking development of drug eluting stents (DES). However, the clinical performance, long-term safety and efficacy of BVS in complex coronary lesions remain uncertain. COMPARE ABSORB, a multicenter, single blind, prospective randomized trial, aims to compare the clinical outcomes between the Absorb BVS and Xience everolimus-eluting metallic stent (EES) in patients with coronary artery disease and a high risk of restenosis. Design COMPARE ABSORB is designed to enroll 2100 patients at up to 45 European sites. Enrolled p…
Predictors of scaffold failure and impact of optimized scaffold implantation technique on outcome: Results from the German-Austrian ABSORB RegIstRy.
2021
Aims We aimed to investigate predictors of scaffold failure and the potential impact of an optimized scaffold implantation technique by means of a learning curve on long-term clinical outcome after bioresorbable scaffold (BRS) implantation and to evaluate predictors of scaffold failure. Methods and results A total of 3326 patients were included in this prospective, observational, multi-center study (ClinicalTrials.gov NCT02066623) of consecutive patients undergoing BRS implantation between November 2013 and January 2016. The 3144 patients completed follow-up after 24 months, 3265 patients were eligible for time-to-event-analysis. Clinical endpoints were major adverse cardiac events-a compos…
Predilation, sizing and post-dilation scoring in patients undergoing everolimus-eluting bioresorbable scaffold implantation for prediction of cardiac…
2017
Aims: The aim of the study was to develop a scoring model to evaluate the quality of bioresorbable vascular scaffold (BVS) implantation and determine the model's usefulness in predicting adverse cardiac events. Methods and results: The implantation technique and clinical outcomes of 1,736 lesions treated with BVS were analysed using the GHOST-EU registry. Predilation, scaffold sizing, and post-dilation (PSP) were scored according to the hazard model derived from the weight of these variables. The primary end-point was a one-year device-oriented composite endpoint (DoCE) composed of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularisation. Def…
TCT-441 Optical Coherence Tomography assessment of the implantation of Everolimus-Eluting Bioresorbable Scaffolds against angiographic assessment: th…
2016
Bioresorbable Vascular Scaffolds (BVS) are the newest generation of stents for use during Percutaneous Coronary Intervention. However, as history has demonstrated, each development in stent technology has been associated with its own specific complications. With BVS, there are reports that recoil is
TCT-419 Usefulness of a scoring system for predicting adverse cardiovascular events in patients undergoing everolimus-eluting bioresorbable scaffolds…
2016
Effect of implantation technique on outcomes in patients receiving bioresorbable scaffolds in various clinical scenarios
2021
ABSTRACT Introduction and objectives: The PSP (pre-dilation, sizing and post-dilation) score, derived from the GHOST-EU registry, has evaluated the relationship between the implantation technique of bioresorbable scaffolds and the clinical outcomes. The objective was to perform an external validation of the PSP technique and to determine its effect on adverse cardiac events in various clinical and anatomical scenarios. Methods: Data from the REPARA registry (2230 patients) were used for external validation, whereas a common database combining REPARA and GHOST-EU (3250 patients) data was used to evaluate the effect of PSP technique in various clinical and anatomical scenarios. PSP-1 and PSP-…
P2695ABSORB bioresorbable scaffold versus Xience metallic stent in acute coronary syndromes with treated with percutaneous coronary intervention. A s…
2019
Abstract Background The safety and efficacy of the ABSORB scaffold in ACS patients remain unclear. The COMPARE-ABSORB trial compares the ABSORB to the Xience stent in lesions and patients at high risk for restenosis Patients with STEMI and urgent PCI for non-STEMI were not excluded. Methods Patients included in the COMPARE-ABSORB trial undergoing PCI for ACS were eligible. Predefined implantation techniques for ABSORB was mandatory. Primary endpoint is target lesion failure (TLF) at 1 year, defined as a composite of cardiac death, target vessel myocardial infarction and clinically indicated target lesion revascularization. Results Of 1670 patients, 842 were treated for ACS. At 1-year, TLF o…